Curve tracer
example 1:
MESFET I-V curves
Updated December
10, 2005
Click
here to go to our main microwave measurements page
Click
here to go to our main curve tracer page
Here we will describe how to
measure the IV curves for a specific MESFET amplifier, but you should
be able to use this procedure for any MESFET or PHEMT transistor.
In the photo below is a MESFET
amplifier made by Marconi, sometime in the 1990s. This part was
available from Bookham, but they are going out of the MMIC business.
It was a feedback amp with ten dB of nearly-flat gain covering 50
MHz to 3.5 GHz, before anyone could even spell "HBT".
Alas, poor P35-4100, we knew you well! Notice from the photo that
you had to construct your own bias tees on both the input and output,
that helped keep the part small and cheap. Borrowing from Monte
Python, let's all sing the GaAs is Great song:
Every crumb GaAs is precious,
every crumb of GaAs is great,
if a crumb is
wasted, God gets so irate!

The other thing that they did
to keep cost low is not to use any via holes, the amp is
grounded using wirebonds ands it is eight mils thick. But we digress...
The amplifier uses a single, 900 um MESFET (you can see three 300
um fingers if you look closely with a good microscope). The source
connection is the pad on the lower right hand side; it is grounded
because this is a common-source amplifier (most FET amps are common
source). Note that the source is actually connected to a gold pad
on the topside of the alumina circuit, this is grounded through
four plated (but unfilled) via holes. The gate connection to the
chip is also the RF input (left side), while the drain connection
is also the RF output (right side). A pair of bias tees are realized
off-chip, using series single-layer 100 pF capacitors to block DC
from RF, and shunt structures consisting of wire-wound inductors
that are connected to multilayer bypass capacitors (10,000 pF).
Not shown are the feedthroughs for injecting the bias voltages.
Ignore the interdigitated filter below the wire-wound inductors,
this is a cheesy test jig that was used for a variety of purposes
by an insane individual.
This is a MESFET
amplifier, so it can handle pretty high operating voltages (5, 6,
7, maybe 8 volts). It is also an example of a depletion mode device.
This means that the channel current is reduced by operating the
gate, in this case, with a negative voltage to get to its normal
operating point. The data sheet calls for 5 volts drain bias, at
90 mA DC current. It's up to you to figure out the proper gate voltage
to get there!
In this example
we will assume you own a Tektronix 370B curve tracer, the best there
is. However, the procedure can be adapted to any model curve tracer
if you will put on your thinking cap for a few minutes. Always
start by disabling the output of the curve tracer to your DUT, and
setting the collector voltage to zero (it's a big knob, you can't
miss it). Turn the collector supply knob all the way counterclockwise
to set it to zero.
Connect the amplifier
to the curve tracer (we'll abbreviate it CT) this way:
Drain of amp=collector of CT
Gate of amp=base of CT
Source of amp (ground on the test jig)=emitter of CT
Cycle the 370B on/off
to clear out whatever settings that last person used. Although the
370B defaults to nearly benign conditions, you should make a habit
out of checking a few things we will describe here; if you have
an older CT, you will need to manually set more of the control knobs.
You should check to see that the polarity of the collector supply
is positive (set to NPN on old curve tracers) and it is in swept
mode as opposed to DC or AC modes. You should make sure that the
step generator has zero offset voltage.
Now set the knobs
on the CT this way (order is not important, but there are five knobs
you need to adjust):
- Set vertical/division to
20 mA (for smaller or larger devices, you may want to change
this setting)
- Set horizontal/division
to 1V
- Set step generator to "voltage"
(not current!), negative polarity, zero steps, 0.5 volts/step.
- Set peak power to 10 watts.
- Set maximum collector voltage
to 16 volts.
Note that all of these settings
may not be appropriate for amplifiers other than the P35-4100, so
you may have to think about what are the best settings to display
your IV device's curves. Now you are ready to begin the measurement.
- Enable the outputs that
are connected to your DUT (you could be plugged in to either
the left side or the right side of the CT).
- Increase the "collector
supply" until you see the IDSS curve (VG=0 volts start
to bend at the knee voltage (approximately 2 volts). Now you
are cooking with gas! Your display should look like this:

Next, change the step generator
setting to add steps to fill out the family of curves. When you
add steps and you don't see more lines, this could mean that you
have the step polarity wrong, or the step size is too small. Below
we have added four steps. Looking good so far:

It's a beautiful
thing. Now go for the gold and crank up the drain voltage to five
volts at IDSS, but don't go too much farther or you may kill the
device. We've added a fifth voltage step here, the device wasn't
completely pinched off. Your curves should look like:

From the above curves, you
can say that IDSS for the device is 156 ma, measured at 2 volts.
You also can say that the transconductance of the device is approximately
100 mS, because there are 2.5 vertical divisions between the voltage
steps near the center of the curves.
If you like, you can change
the step size to 200 millivolts/step for more detail. We recommend
that you decrease the collector (drain) voltage to zero before
you change the step generator knob. Then slowly increase the drain
voltage and add more steps until you get the following curves
(we've maxed out the step generator at ten steps).

A nice set of curves indeed.
The hysteresis in the curves is due to the capacitance in the
bias tees, which is a necessary evil because it helps keep the
device stable. From this curve, we'd say that the pinch-off voltage
VPO is -2 volts (looking at the bottom line, which is 10 steps
x -0.2 volts). And now we can see that the proper gate voltage
to get 90 mA at 5 volts is approximately -0.7 volts. This
is extrapolated between the fourth and fifth curves from the top
(-0.6 volts and -0.8 volts).
Now it's time to measure gate-drain
breakdown voltage. We have to turn some knobs again. What do you
do first? Turn down the collector voltage to zero, and disable
the output to your device. Again, we stress, this should become
a habit.
In this measurement, we want
the source (emitter) terminal to be open circuit. You need to
set the output to "emitter open", this shuts off the
step generator as well (which is not needed for two-terminal measurements
such as this). Now we have to explain a weird convention... the
breakdown voltage between gate and drain is a negative voltage.
The way the device is hooked up, you will be sending a positive
voltage between the drain and the gate, which is the same thing.
But because we want to report a negative voltage, most engineers
invert the display to the upper right corner. Now when you increase
the collector voltage, the curve will sweep to the left and down.
Time to adjust some knobs:
- Set horizontal/division
to 2 volts
- Set current/division to
1 ma
- Set peak power to 0.04 watts
(this is done by increasing the collector resistor value on
older CTs)
OK, enable the DUT and start
increasing the collector voltage slowly... The DUT should act
like an open circuit (horizontal line) for a few volts, then breakdown
should occur. You don't want to have a lot of current this way
(just a milliamp or two) or your device will be damaged. In the
case of the curve below, we measure Vbr at 0.9 ma (1 ma/mm periphery)
and we get -14.5 volts.

Below is plotted the forward
conduction of the gate drain junction. No need to measure this,
we plotted it to show you what happens if you have the polarity
wrong in as breakdown measurement. Conduction begins at about
0.5 volts for a Schottky junction on GaAs. It takes quite a few
milliamps to blow up a device this way, but imagine what happens
if you switch the polarity of your gate power supply to an amplifier
and it is set at +1 volt instead of -1 volt. It will hit whatever
current limit you have, and if that current limit is hundreds
of milliamps, good bye amplifier!

Now it's time to go for the
gold medal of I-V curves: determining the true open-channel current
of a FET. To do this, the top curve must be forward-biased to
approximately 0.5 volts (remember, we don't want to run a lot
of current into the gate, so let's not get carried away).
What do you do first? Turn
down the collector voltage to zero, and disable the output to
your device.
Now reconfigure the setup exactly
how we first had it, except increase the current/division to 50
ma/division. The family of curves should now look like this:

Now it's time to get fancy
and use the offset feature of the step generator.
- Set the offset to "oppose"
(we want to put a positive voltage on the negative step.
- Set the offset to 500 millivolts.
Now trace the curves and you
will see the "hidden" current-carrying capacity of the
amplifier. Imax is 225 ma, measured at 2 volts.

There, that wasn't so hard. Repeat
after us... the curve tracer is your friend!
|