Rat-race
versus Gysel
Updated March
25, 2011
Click
here to go to our main page on power splitters and couplers
Click
here to go to our main page on Gysel power splitters
Click
here to go to our main page on rat-race power splitters
New for April 2011! We
got the idea for this page from Richard, thanks!
On this page we will unify the
analysis of these two splitters, which are really quite similar
(both are based on a ring that is 1.5 wavelengths, with taps at
various quarterwave
spacings).
Below is the most basic rat-race
schematic, the "ring impedance" is set to SQRT(2)*Z0.

Note that we've set up two "matching"
equations. IN this sense, we are talking about matching two signals
to each other, not the other sense, where we would be looking at
their impedance match. Does everyone know the difference between
signal matching and signal tracking? A subject for anotheer day...
As a 180 degree, 3 dB splitter,
port 1 woul;d be the input, and ports 2 and 3 are the outputs. Port
4 is terminated. But you can also feed Port 4, and an in-phase split
occurs at ports 2 and 3.
Let's first look at the return
loss and isolations, by symmetry, there are only three different
plots to look at.

Now we will compare the transmission
parameters, based on feeding port 1 (180 split) or port 2 (in-phase
split), side by side. Click images to zoom in.
|

Transmission
to ports 2 and 3
|

Transmission to ports
2 and 3
|
|

Matching
between ports 2 and 3
|

Matching
between ports 3 and 2
|
|

Relative
phases, ports 2 and 3
|

Relative phases, ports
2 and 3
|
|
These
results are when Port 1 is fed
|
These
results are when Port 4 is fed
|
Next we note that if you can
have a single termination of 50 ohms at port 1, you could add a
second termination at a new location, port 5 (lower right corner
of schematic, but you must increase the impedance of the terminated
ports to 100 ohms. Now the coupler behaves better! By the way, Gysel
pointed out in his 1975 paper that the terminations don't have to
be 50 ohms, but he made them 50 ohms for convenience (where's that
100 ohm load when you need it?)

Below are the transmission coefficient
and isolation and return losses. Note that in the present example,
Port 4 is still the input. Also note that the reflection coefficient
that the termination sees at Port 1 is not a match, this is a don't
care situation! We have achieved perfect balance in the two transmission
coefficients S24 and S34, what more could you ask for?
More to come!
|